50 Kilogramm Hobbock
- Package unit
- 50 Kilogramm Hobbock
- Item no.
- 17161
- EAN
- 4032167171619
Fluid grease ZSA for trucks and central lubrication systems with strong low-temperature performance, wear protection, and DIN 51 826 classification.
Fluid grease ZSA GP 00 K-40 is designed for central lubrication systems and mechanically stressed lubrication points in commercial vehicles. The product was specifically developed for applications requiring both good flow behavior at low temperatures and reliable wear protection.
In truck central lubrication systems, pumpability is critical. A grease that cannot be properly delivered in winter is of little use. That is exactly why low-temperature performance is so important here.
For suitable systems from Mercedes-Benz, MAN, and Willy Vogel, this fluid grease is a specialized practical solution.
Suitable for central lubrication systems and mechanically stressed lubrication points in commercial vehicles where DIN 51 826 GP 00 K-40, MB 264.0, or MAN 283 Li-P 00/000 are required.
Why does a central lubrication system require special fluid grease?
Because pumpability and even distribution within the piping system are essential.
What does GP 00 K-40 mean?
This is the DIN classification for a fluid grease designed for low-temperature operation.
Is this grease intended for standard grease guns?
The focus is clearly on central lubrication systems and systems designed for this purpose.
| Property | Value |
|---|---|
| Color / appearance | light green, smooth |
| Thickener | Lithium soap |
| Operating temperature range | -40 °C to +120 °C |
| NLGI grade | 00 |
| Base oil viscosity at 40 °C | 68 mm2/s |
| Dropping point | > 160 °C |
| Worked penetration 60 strokes | 400 - 430 0.1 mm |
| Worked penetration delta PW 5000-60 | < 20 0.1 mm |
| Water resistance at 90 °C | rating 1 |
| Flow pressure at -35 °C | 50 hPa |
| Corrosion effect on copper 24 h / 100 °C | corrosion grade 1 |
| Four-ball weld load | 2400 N |
| Elastomer test SRE-NBR 34, hardness change | -2 Sha |
| Elastomer test SRE-NBR 34, volume change | +6.8 % |
Store containers clean, dry, and preferably temperature-controlled. Protect from direct sunlight, frost, and strong temperature fluctuations. Reseal opened containers tightly and use only clean dispensing equipment to prevent contamination of the fluid grease in central lubrication systems.